- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction >=0.99
- Output power factor 0.9
- Wide input voltage (130 V - 280 V)
- Converter mode available
- Generator compatible
- Smart SNMP works well with either USB or RS-232 together display allows easy monitoring and access of UPS status
- Adjustable battery numbers 18, 19, 20 pcs.
Technical data
| MODEL | Champ RM 6KL | Champ RM 10KL |
| PHASE | Single phase with ground | |
| CAPACITY | 6000VA / 5400W | 10000VA / 9000W |
| PARALLEL CAPABILITY | NO | |
| INPUT | ||
| Nominal Voltage | 208V/220V/230V/240V | |
| Voltage Range | 110-300 Vac ±3% @ 50% load 176-300 Vac ±3% @ 100% load | |
| Frequency Range | 46~54 Hz or 56~64Hz | |
| Power Factor | ≧ 0.99 @ 100% load | |
| OUTPUT | ||
| Output Voltage | 208V/220V/230V/240V | |
| AC Voltage Regulation (Batt. Mode) | ± 1% | |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
| Current Crest Ratio | 3:1 | |
| Harmonic Distortion | ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) | |
| Transfer time AC mode to Battery mode | zero | |
| Transfer time Inverter to Bypass | zero | |
| Waveform (Batt. Mode) | Pure Sine Wave | |
| Overload AC Mode | - | |
| Overload Battery Mode | - | |
| EFFICIENCY | ||
| AC Mode | 92.00% | 93.00% |
| ECO Mode | NO | NO |
| Battery Mode | 90.00% | 91.00% |
| BATTERY | ||
|
| Standard model | |
| Battery Type | N/A | |
| Numbers | ||
| Typical Recharge Time | ||
| Charging Current (max.) | ||
| Charging Voltage | ||
|
| Long-run model | |
| Battery Type | Depending on the capacity of external batteries | |
| Numbers in string | 16 - 20 pcs. (Adjustable) | |
| Charging Current (max.) | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) | |
| Charging Voltage | 218,4VDC ± 1% (Based on 16pcs batteries) | |
| INDICATORS | ||
| LCD Panel | Last level, Battery level, AC mode, Battery mode, Bypass mode and Fault conditions | |
| ALARM | ||
| Battery mode | Sounding every 4 seconds | |
| Low battery | Sounding every second | |
| Overload | Sounding twice every second | |
| Fault | Continuosly sounding | |
| AC input & Output connectors | ||
| AC Input connector | Terminal block | |
| AC Output connector | Terminal block | |
| STANDARDS | ||
| Safety / EMC | IEC 62040-1 / IEC 62040-2 / CE | |
| PHYSICAL | ||
|
| Standard model | |
| Dimension, D X W X H (mm) | N/A | |
| Net Weight (kgs) | N/A | |
|
| Long-run model | |
| Dimension, D X W X H (mm) | UPS unit - 530 x 438 x 88 mm (2U); Battery pack - 668 x 438 x 88 mm (2U) | 580 x 438 x 133 mm (3U) |
| Net Weight (kgs) | UPS unit - 15Kg; Battery pack - 48Kg | 18Kg |
| ENVIRONMENT | ||
| Operation Temperture | 0-40°C | |
| Operation Humidity | <95% and non-condersing | |
| Noise Level | Less than 50dB @ 1 meter | Less than 58dB @ 1 meter |
| MANAGEMENT | ||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC | |
| Optional SNMP | Power management from SNMP manager and web browser | |
Backup time table
| UPS model | Battery bank | Back up time with load, min | |||
| 25% | 50% | 75% | 100% | ||
| Champ RM 6KL | BB-192/09RT(16pcs 9Ah) | 40 | 15 | 9 | 6 |
| BB-240/10RT(20pcs 10Ah) | 68 | 27 | 18 | 12 | |
| Champ RM 10KL | BB-192/09RT(16pcs 9Ah) | 21 | 8 | 4 | 2 |
| BB-240/10RT(20pcs 10Ah) | 40 | 16 | 9 | 6 | |